The first experience of using non-invasive real-time mapping in an electrophysiology laboratory for treatment of ventricular arrhythmia

https://doi.org/10.20538/1682-0363-2021-3-213-218

Abstract

 A clinical case of treatment for ventricular arrhythmia from the right ventricular outflow tract using non-invasive real-time electrophysiological mapping and the “Astrocard” navigation system (“Meditek”, Russia) is presented. This clinical case demonstrates the accuracy of non-invasive real-time mapping for the diagnosis and treatment of ventricular arrhythmias. 

About the Authors

E. A. Artyukhina
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

 27, Bolshaya Serpukhovskaya Str., Moscow, 117997, Russian Federation 



E. V. Dedukh
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

 27, Bolshaya Serpukhovskaya Str., Moscow, 117997, Russian Federation 



M. V. Yashkov
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

 27, Bolshaya Serpukhovskaya Str., Moscow, 117997, Russian Federation 



A. Sh. Revishvili
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

 27, Bolshaya Serpukhovskaya Str., Moscow, 117997, Russian Federation 



References

1. Zhong L., Lee Y.H., Huang X.M., Asirvatham S.J, Shen W.K., Friedman P.A., Hodge D.O., Slusser J.P., Song Z.Y., Packer D.L., Cha Y.M. Relative efficacy of catheter ablation vs antiarrhythmic drugs in treating premature ventricular contractions: a single-center retrospective study. Heart Rhythm. 2014; 11 (2):187–193. DOI: 10.1016/j.hrthm.2013.10.033.

2. Komatsu Y., Nogami A., Shinoda Y, Masuda K., Machino T., Kuroki K., Yamasaki H., Sekiguchi Y., Aonuma K. Idiopathic ventricular arrhythmias originating from the vicinity of the communicating vein of cardiac venous systems at the left ventricular summit. Circ. Arrhythm. Electrophysiol. 2018; 11 (1): e005386. DOI: 10.1161/CIRCEP.117.005386.

3. Anter E., Frankel D.S., Marchlinski F.E., Dixit S. Effect of electrocardiographic lead placement on localization of outflow tract tachycardias. Heart Rhythm. 2012; 9 (5): 697–703. DOI: 10.1016/j.hrthm.2011.12.007.

4. Inaba T., Nakazawa Y., Yoshida K., Kato Y., Hattori A., Kimura T., Hoshi T., Ishizu T., Seo Y., Sato A., Sekiguchi Y., Nogami A., Watanabe S., Horigome H., Kawakami Y., Aonuma K. Routine clinical heart examinations using SQUID magnetocardiography at university of tsukuba hospital. Supercond. Sci. Technol. 2017; 30 (11). DOI: 10.1088/1361-6668/aa8c26.

5. Ito Y., Shiga K., Yoshida K., Ogata K., Kandori A., Inaba T., Nakazawa Y., Sekiguchi Y., Tada H., Sekihara K., Aonuma K. Development of a magnetocardiography-based algorithm for discrimination between ventricular arrhythmias originating from the right ventricular outflow tract and those originating from the aortic sinus cusp: a pilot study. Heart Rhythm. 2014; 11 (9): 1605–1612. DOI: 10.1016/j.hrthm.2014.05.032.

6. Jamil-Copley S., Bokan R., Kojodjojo P., Qureshi N., KoaWing M., Hayat S., Kyriacou A., Sandler B., Sohaib A., Wright I., Davies D.W., Whinnett Z., Peters S.N., Kanagaratnam P., Lim P.B. Noninvasive electrocardiographic mapping to guide ablation of outflow tract ventricular arrhythmias. Heart Rhythm. 2014; 11 (4): 587–594. DOI: 10.1016/j.hrthm.2014.01.013.

7. Cakulev I., Sahadevan J., Arruda M., Goldstein R.N., Hong M., Intini A., Mackall J.A., Stambler B.S., Ramanathan C., Jia P., Strom M., Waldo A.L. Confirmation of novel noninvasive high-density electrocardiographic mapping with electrophysiology study: implications for therapy. Circ. Arrhythm. Electrophysiol. 2013; 6 (1): 68–75. DOI: 10.1161/CIRCEP.112.975813.

8. Revishvili A.S. , Wissner E., Lebedev D.S., Lemes C., Deiss S., Metzner A., Kalinin V.V., Sopov O.V., Labartkava E.Z., Kalinin A.V., Chmelevsky M., Zubarev S.V., Chaykovskaya M.K., Tsiklauri M.G., Kuck K.H. Validation of the mapping accuracy of a novel non-invasive epicardial and endocardial electrophysiology system. Europace. 2015; 17 (8): 1282–1288. DOI: 10.1093/europace/euu339.

9. Wissner E., Saguner A.M., Metzner A., Chmelesky M., Tsyganov A., Deiss S., Maurer T., Kuck K.H. Radiofrequency ablation of premature ventricular contractions originating from the aortomitral continuity localized by use of a novel noninvasive epicardial and endocardial electrophysiology system. Heart Rhythm Case Rep. 2016; 2 (3): 255–257. DOI: 10.1016/j.hrcr.2016.02.004.

10. Wang Y., Cuculich P.S., Zhang J., Desouza K.A., Vijayakumar R., Chen J., Faddis M.N., Lindsay B.D., Smith T.W., Rudy Y. Noninvasive electroanatomic mapping of human ventricular arrhythmias with electrocardiographic imaging. Sci. Transl. Med. 2011; 3 (98): 98ra84. DOI: 10.1126/scitranslmed.3002152.

11. Wissner E., Revishvili A., Metzner A., Tsyganov A., Kalinin V., Lemes C., Saguner A.M., Maurer T., Deiss S., Sopov O., Labarkava E., Chmelevsky M., Kuck K.H. Noninvasive epicardial and endocardial mapping of premature ventricular contractions. Europace. 2017; 19 (5): 843–849. DOI: 10.1093/europace/euw103.

12. Duchateau J., Sacher F., Pambrun T., Derval N., Chamorro-Servent J., Denis A., Ploux S., Hocini M., Jaïs P., Bernus O., Haïssaguerre M., Dubois R. Performance and limitations of noninvasive cardiac activation mapping. Heart Rhythm. 2019; 16 (3): 435–442. DOI: 10.1016/j.hrthm.2018.10.010.


Review

For citations:


Artyukhina E.A., Dedukh E.V., Yashkov M.V., Revishvili A.Sh. The first experience of using non-invasive real-time mapping in an electrophysiology laboratory for treatment of ventricular arrhythmia. Bulletin of Siberian Medicine. 2021;20(3):213-218. https://doi.org/10.20538/1682-0363-2021-3-213-218

Views: 628


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1682-0363 (Print)
ISSN 1819-3684 (Online)